Minolta Ls 100 Communication Manual

Data communication. Multiple-measurement-averaging mode; remote-control socket; can supply to CS-100A. Power source. 6 AA-size batteries or included. Compact, portable, multi-function data processor to increase the versatility of Minolta Chroma Meter. Additional Color Notations. When DP-101 is. Cetus Compiler Installation Definition.

Full text of ' NISTIR 6638 AlllOb I R0WEIM#' Automated Luminance-Meter Control Software for Electronic-Display Measurements J. Matthew Treinen NIST National Institute of Standards and Technology Technology Administration, U.S. Department of Commerce 3.0 Seconds Sample ft Advanced Configurations STOP/ABORT PROGRAM Tabbed Info Box RS-232 Comm. Error Indicators • Reset Detector Memory Clear Graph? # Error Codes Tabbed Info Box Visible?

Detection Status # of Mes. R T aken Adv.

Box Visible?% REFERENCE VALUE CONFIGURATION Get Current 1 00% Reference Value • Store Current Reading as 1 00% Reference ^ Status Store Value Below as the 100% Reference Value ^ (6 char) Status USER CALIBRATION CONFIGURATION Read Current User Calibration Value • Store Value Below as Calibrated Value for Last Measurement ^ (6 char) Status COLOR CORRECTION FACTOR CONFIGURATION Get Current C.C.F » r Store This Value to C.C.F ^ (5 char) Status 0.001.

From psychopy import logging logging. Driver Solution Pack 14 Iso Free Download. SetLevel ( logging.

ERROR ) # error messages only logging. SetLevel ( logging. INFO ) # more info logging.

SetLevel ( logging. DEBUG ) # log all communications If you’re using a keyspan adapter (at least on OS X) be aware that it needs a driver installed. Otherwise no ports wil be found. Error messages: ERROR: Couldn't connect to Minolta LS100/110 on ____: This likely means that the device is not connected to that port (although the port has been found and opened). Check that the device has the [ in the bottom right of the display; if not turn off and on again holding the F key.

ERROR: No reply from LS100: The port was found, the connection was made and an initial command worked, but then the device stopped communating. If the first measurement taken with the device after connecting does not yield a reasonble intensity the device can sulk (not a technical term!). The “[” on the display will disappear and you can no longer communicate with the device. Turn it off and on again (with F depressed) and use a reasonably bright screen for your first measurement.

Subsequent measurements can be dark (or we really would be in trouble!!). CheckOK ( msg ) Check that the message from the photometer is OK. If there’s an error show it (printed). Then return True (OK) or False. ClearMemory ( ) Clear the memory of the device from previous measurements getLum ( ) Makes a measurement and returns the luminance value measure ( ) Measure the current luminance and set.lastLum to this value sendMessage ( message, timeout=5.0 ) Send a command to the photometer and wait an alloted timeout for a response. SetMaxAttempts ( maxAttempts ) Changes the number of attempts to send a message and read the output.

Typically this should be low initially, if you aren’t sure that the device is setup correctly but then, after the first successful reading, set it higher. SetMode ( mode='04' ) Set the mode for measurements. Returns True (success) or False ‘04’ means absolute measurements.

‘08’ = peak ‘09’ = cont See user manual for other modes.